Site Description
Basin 2 is a former marine naval dock that covers an area of approximately 8 hectares with a relatively uniform depth of around 9m. The dock is surround by a mix of residential and commercial properties. The dock is managed by Chatham Maritime Trust who operate a water sports centre for a range of contact water sports. Given the use of the dock, that includes youth water sports activities, a key management objective was to maintain a high water quality status to ensure protection of site users.
Management Issues
The dock displayed a range of management issues that impacted on its amenity function and water quality status. These included:
- Occasional development of ‘Red Tide’ algae blooms; and
- Deoxygenation of the lower water column during the summer months due to thermal stratification. This lead to water quality issues, restriction on marine ecology and development of hydrogen sulphide gas and odour.

The Solution
An ISS-Flowthrough diffused aeration system with 15(no) diffusers supplied with air from a single compressor was developed for the dock. The design of the system had to be such that it did not interfere with amenity use within the dock or its occasional use for mooring of large vessels. The primary purpose of the system was to provide complete mixing of the dock area. This removed the negative impacts of thermal stratification on water quality conditions and marine ecology. Additionally, this prevented gas and odour generation.
The aeration system installation was combined with a pre and post installation monitoring for Bathing Water Quality Standards together with measurement of in-situ physico-chemical measurements through the water column (i.e. temperature, dissolved oxygen and salinity).
The Results
Water quality monitoring conducted in both pre and post aeration / mixing periods allowed the effectiveness of mixing to be established. The effects are summarised below:
- Microbiological Bathing Water Quality has been recorded as consistently excellent and no potential harmful algae blooms have been recorded since installation and operation of the aeration system;
- Mixing removed stratification effects and allowed good dissolved oxygen concentrations to develop in the lower water column;
- Marina fauna has developed down the lower dock walls and across the bed the dock where it was previously absent. The increased abundance of filter feeding organisms has resulted in marked increases in water transparency; and